Parameters to Record on the Job Card
The table below gives typical working values used for stack squaring on standard corrugated converting equipment. They are starting points for a setup, not acceptance limits; the limits for a given order should be taken from the job specification and the measured condition of the board being run.
Parameter | Typical working value | How it is used |
Squaring tolerance | plus or minus 2 millimetres | Verify against the machine specification and the board grade in use. |
Bundle count | 10 to 30 sheets | Measure at production speed after the line has warmed up. |
Ejection stroke | matched to bundle length | Record on the setup sheet at the start of each order. |
Stack height limit | below 1800 millimetres | Recheck after any tooling or material change. |
Each value should be recorded together with the board grade, flute type and line speed at which it was measured. Measurements should be taken with calibrated instruments at a defined position on the sheet, since a reading from the edge and a reading from the centre of a warped sheet are not the same result.
Working Principle Behind Stack squaring
The stacker and bundle former works within a narrow window defined by squaring plate and layer alignment. When squaring tolerance is held at plus or minus 2 millimetres, the process stays repeatable; as soon as the value leaves that window, the first visible sign is skewed pile. Understanding that chain of cause and effect is more useful than memorising a single number, because the correct value shifts with board grade, flute type and line speed.
Ejection pusher and bundle height interact with the setting, so an adjustment made to one of them should never be treated as independent. For example, a change that improves the result at low speed can behave differently at production speed, which is why the same check is repeated after the line has stabilised. Measurements should be taken with calibrated instruments at a defined position on the sheet, since a reading from the edge and a reading from the centre of a warped sheet are not the same result.
Routine Checks That Protect the Setting
Stable stack squaring depends on clean, aligned and correctly lubricated hardware. Inspection of squaring plate and layer alignment should be part of the planned schedule, with the measured value of squaring tolerance recorded each time so that a trend can be seen. A trend towards the tolerance limit is a better trigger for service than a fixed calendar date.
Additional Practical Notes
Stack squaring is checked against the job card at the start of each order, and the reading is filed with the board grade and the line speed at which it was taken. Trial sheets used for setup are counted separately, so the true waste of a changeover stays visible in the shift figures.
Shift Level Checklist
Confirm the job recipe, the board grade and the drawing before the first sheet of stack squaring is checked.
Verify squaring tolerance against the setup sheet at the start of each shift rather than after a complaint.
Record the measured result of every first off sample so that drift can be seen across orders.
Keep squaring plate and layer alignment clean and inspect them for wear at the defined interval.
Watch for skewed pile and correct one variable at a time, measuring after each change.
File the final setting, the correction made and the reason for it at handover.
Summary for the Shift
Stable stack squaring comes from a measured target, a defined tolerance and a routine that is followed on every order. Keep squaring tolerance at plus or minus 2 millimetres, verify the first off sample, watch for skewed pile and record every correction. Those habits do more for output and consistency than a single large adjustment made after a complaint.
Figures quoted in this article are typical working values for standard corrugated converting equipment. They should be verified against the specification of the machine in use, the board grade being processed and the conditions measured on the shift before they are used as acceptance limits.
References
[1] ISO 12647-2:2013, Graphic technology - Process control for the production of half-tone colour separations, proof and production prints - Part 2: Offset lithographic processes.
[2] ISO 9001:2015, Quality management systems - Requirements.
[3] TAPPI T 804 om-12, Compression test of fiberboard shipping containers.
[4] TAPPI T 839 pm-13, Edgewise compressive strength of corrugated fiberboard (short column test).
[5] ASTM D642-15, Standard Test Method for Determining Compressive Resistance of Shipping Containers, Components, and Unit Loads.
[6] EN 415-1:2014, Safety of packaging machines - Part 1: Terminology and classification of packaging machines and associated equipment.
[7] IEC 60204-1:2016, Safety of machinery - Electrical equipment of machines - Part 1: General requirements.