Water Based Ink pH, Amine Balance and Foam Control on Press
Summary: Water based ink pH control explained for corrugated converting equipment: working ranges, setup sequence, tolerance control and corrective action for foam build up.
- Category: Company News
- Author: Xinshida
- Published: 2026-11-26 10:07:01
- Views: 151
Key Parameters and Working Ranges
The table below gives typical working values used for water based ink pH control on standard corrugated converting equipment. They are starting points for a setup, not acceptance limits; the limits for a given order should be taken from the job specification and the measured condition of the board being run.
Parameter | Typical working value | How it is used |
Ink ph | 8.5 to 9.2 | Verify against the machine specification and the board grade in use. |
Viscosity on a flow cup number 3 | 18 to 24 seconds | Measure at production speed after the line has warmed up. |
Ink temperature | 20 to 25 degrees Celsius | Record on the setup sheet at the start of each order. |
Foam height in the tank | below 20 millimetres | Recheck after any tooling or material change. |
Each value should be recorded together with the board grade, flute type and line speed at which it was measured. Where a limit is given as a range, the lower half of the range usually gives the safer starting point for a new board grade; the setting can then be raised only after the measured result confirms that it is needed.
What Actually Happens at the Ink circulation system
The ink circulation system works within a narrow window defined by pH value and amine balance. When ink pH is held at 8.5 to 9.2, the process stays repeatable; as soon as the value leaves that window, the first visible sign is foam build up. Understanding that chain of cause and effect is more useful than memorising a single number, because the correct value shifts with board grade, flute type and line speed.
Viscosity and surface tension interact with the setting, so an adjustment made to one of them should never be treated as independent. For example, a change that improves the result at low speed can behave differently at production speed, which is why the same check is repeated after the line has stabilised. In a working corrugated plant, the result is decided as much by the discipline of the shift as by the specification of the machine. Settings that are measured and written down stay stable; settings that are judged by eye drift from one operator to the next.
Records, Traceability and Repeat Orders
Every order should leave behind a record of ink pH, viscosity on a flow cup number 3, the board grade and the measured first off result. When the order returns, that record shortens setup and reduces trial sheets, which is the most direct saving available for short run work.
Energy, Consumables and Cost Impact
A setting that drifts costs more than the reject sheets it produces. Extra trial sheets, rework, ink or adhesive top ups and unplanned stoppages all follow from unstable water based ink pH control. Holding ink pH at 8.5 to 9.2 reduces that loss more reliably than any single downstream saving.
Additional Practical Notes
Water based ink pH control is checked against the job card at the start of each order, and the reading is filed with the board grade and the line speed at which it was taken. Trial sheets used for setup are counted separately, so the true waste of a changeover stays visible in the shift figures.
Shift Level Checklist
Confirm the job recipe, the board grade and the drawing before the first sheet of water based ink pH control is checked.
Verify ink pH against the setup sheet at the start of each shift rather than after a complaint.
Record the measured result of every first off sample so that drift can be seen across orders.
Keep pH value and amine balance clean and inspect them for wear at the defined interval.
Watch for foam build up and correct one variable at a time, measuring after each change.
File the final setting, the correction made and the reason for it at handover.
Practical Summary
Stable water based ink pH control comes from a measured target, a defined tolerance and a routine that is followed on every order. Keep ink pH at 8.5 to 9.2, verify the first off sample, watch for foam build up and record every correction. Those habits do more for output and consistency than a single large adjustment made after a complaint.
Figures quoted in this article are typical working values for standard corrugated converting equipment. They should be verified against the specification of the machine in use, the board grade being processed and the conditions measured on the shift before they are used as acceptance limits.
References
[1] ISO 12647-2:2013, Graphic technology - Process control for the production of half-tone colour separations, proof and production prints - Part 2: Offset lithographic processes.
[2] ISO 9001:2015, Quality management systems - Requirements.
[3] TAPPI T 804 om-12, Compression test of fiberboard shipping containers.
[4] TAPPI T 839 pm-13, Edgewise compressive strength of corrugated fiberboard (short column test).
[5] ASTM D642-15, Standard Test Method for Determining Compressive Resistance of Shipping Containers, Components, and Unit Loads.
[6] EN 415-1:2014, Safety of packaging machines - Part 1: Terminology and classification of packaging machines and associated equipment.
[7] IEC 60204-1:2016, Safety of machinery - Electrical equipment of machines - Part 1: General requirements.
扫二维码用手机看
Address: Dongguang County, Cangzhou City, Hebei Province, China
Phone: +86 13930771388
WhatsApp: +86 13930771388
Email: 1971637272@qq.com
Website: https://www.xinshidamfg.com
- Follow Xinshida -
Copyright © 2019 Cangzhou Xinshida Machinery Equipment Co., Ltd.